Best CP34I309SB Installation Guide

Browse online or download Installation Guide for Cooker hoods Best CP34I309SB. Best CP34I309SB Installation Guide [pt] User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
CP34, CP35 AND CP37 SERIES
HB0078
INSTALLATION INSTRUCTIONS
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12 AND 13.
READ AND SAVE THESE INSTRUCTIONS
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
To register your product online or for additional information visit www.BestRangeHoods.com
SV08544 rev. 09
! !
Page view 0
1 2 3 4 5 6 ... 47 48

Summary of Contents

Page 1 - CP34, CP35 AND CP37 SERIES

CP34, CP35 AND CP37 SERIESHB0078INSTALLATION INSTRUCTIONSINTENDED FOR DOMESTIC COOKING ONLYINSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.HOMEOWNER: USE

Page 2 - WARNING

1014. REINSTALL BLOWER(S) (CONT’D)Plug the blower(s) in.HE0085ALL MODELS15. REINSTALL BOTTOM PANELLift the bottom panel and engage the power pack me

Page 3

1117. REINSTALL BAFFLE FILTERSCAUTIONRemove protective plastic film covering filters before installing them.NOTE: Assemble the metal handles to the f

Page 4 - 3. CUSTOM HOOD PREPARATION

1219. USE AND CAREBaffle FiltersThe baffle filters should be cleaned frequently. Use a warm detergent solution. Wash more often if your cooking style

Page 5 - 5. REMOVE FILTERS

1320. OPERATIONAlways turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clea

Page 6 - 8. REMOVE KNOCK-OUT OPENING

1421. WARRANTYONE-YEAR LIMITED WARRANTYBroan-NuTone LLC (“Broan-NuTone”) warrants to the original consumer purchaser of its products that such product

Page 7 - 11. CONNECT WIRING

1522. WIRING DIAGRAMLINENEUTRALGROUND120 V ACWHTMBRNBLUREDBLKMBRNBLUREDBLKWHTSPEEDCONTROL HSTHERMOSTATBLUBLKBLKBLUBLKWHTWHTWHTWHTBLKBLKYELYELLAMPLAMPS

Page 8 - 12. REMOVE BLOWER(S)

1623. SERVICE PARTSBest CP34, CP35& CP37 SeriesHL011010111215141613123456789REPLACEMENT PARTS AND REPAIRSIn order to ensure your unit remains in g

Page 9 - 14. REINSTALL BLOWER(S)

SÉRIES CP34, CP35 ET CP37HB0078GUIDE D’INSTALLATIONCONÇUES POUR USAGE DOMESTIQUE SEULEMENTINSTALLATEUR : LAISSER CE GUIDE AU PROPRIÉTAIRE.PROPRIÉTAIRE

Page 10 - 15. REINSTALL BOTTOM PANEL

18AFIN DE RÉDUIRE LES RISQUES D’INCENDIE, D’ÉLECTROCUTION OU DE BLESSURES CORPORELLES, SUIVEZ LES DIRECTIVES SUIVANTES :1. N’utilisez cet appareil que

Page 11 - 18. LIGHT BULBS

19HL0122- SYSTÈMES DE HOTTES ENCASTRABLES -CP34, CP35 ET CP37MODÈLE 634 OU 644(CAPUCHON DE TOIT)MODÈLE 643(CAPUCHON MURAL 8 PO ROND)MODÈLE 418(COUDE A

Page 12 - 19. USE AND CARE

2TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:1. Use this unit only in the manner intended by the manufactu

Page 13 - 20. OPERATION

201. PRÉPARER L’INSTALLATIONDéterminer à quel endroit et comment les conduits seront installés. Un accès au dessus de la hotte est préférable pour le

Page 14 - 21. WARRANTY

213. PRÉPARER L’ARMOIRE POUR HOTTE (SUITE)Afin de minimiser l’espace autour de la hotte encastrable, mesurer la longueur et profondeur de celle-ci et

Page 15 - 22. WIRING DIAGRAM

226. RETIRER LA GOUTTIÈREA. Soulever la goutière pour la dégager du panneau inférieur.B. Glisser la gouttière complètement vers la gauche ou la droit

Page 16 - 23. SERVICE PARTS

2310. INSTALLER L’ADAPTATEUR ET LE VOLET (MODÈLE CP37 SEULEMENT)À l’aide de 2 vis n° 8 x 3/8 po fournies dans le sac de pièces, assembler l’adaptateu

Page 17 - SÉRIES CP34, CP35 ET CP37

2412. RETIRER LE(S) VENTILATEUR(S)Afin de faciliter l’alignement de la hotte encastrable avec des conduits déjà installés, débrancher et désassembler

Page 18 - ATTENTION

2513. INSTALLER LA HOTTE ENCASTRABLEATTENTIONPrendre soin de ne pas gauchir les conduits en installant la hotte encastrable.À l’aide des vis plaquées

Page 19 - CP34, CP35 ET CP37

2614. REMETTRE EN PLACE LE(S) VENTILATEUR(S) (SUITE)Rebrancher le(s) ventillateur(s).HE0085TOUS LES MODÈLES15. REMETTRE EN PLACE LE PANNEAU INFÉRIEU

Page 20 - 1. PRÉPARER L’INSTALLATION

2717. RÉINSTALLER LES FILTRES À CHICANEATTENTIONAvant d’installer les filtres à chicane, retirer le plastique protecteur de ceux-ci.NOTE : Assembler

Page 21 - 5. RETIRER LES FILTRES

2819. ENTRETIENFiltres à chicaneLes filtres à chicane doivent être nettoyés fréquemment. Utiliser une solution d’eau chaude et de détergent. Nettoyer

Page 22 - 6. RETIRER LA GOUTTIÈRE

2920. FONCTIONNEMENTToujours mettre en marche le ventilateur avant de commencer la cuisson afin d’établir une circulation d’air dans la cuisine. Laiss

Page 23 - 11. BRANCHEMENT ÉLECTRIQUE

3HL0122- CP34, CP35 AND CP37 POWER PACK SYSTEMS -MODEL 634 OR 644(ROOF CAP)MODEL 643(8” ROUND WALL CAP)MODEL 418 (10” ROUND ADJUSTABLE ELBOW)MODEL 410

Page 24 - MODÈLE CP37

3021. GARANTIEGARANTIE LIMITÉE DE UN ANBroan-NuTone LLC (« Broan-NuTone ») garantit à l’acheteur consommateur initial de ses produits qu’ils sont exem

Page 25

3122. SCHÉMA ÉLECTRIQUELIGNENEUTREMISE ÀLA TERRE120 V C ABMBRBLRNMBCOMMANDEDE VITESSE HSTHERMOSTATBLNBLNBBBBNNJJLAMPEINTERRUPTEURD’ÉCLAIRAGEL

Page 26 - TOUS LES MODÈLES

3223. PIÈCES DE REMPLACEMENTBest séries CP34, CP35et CP37HL011010111215141613123456789PIÈCES DE REMPLACEMENT ET SERVICEPour assurer le bon fonctionne

Page 27 - 18. AMPOULES

SERIES CP34, CP35 Y CP37HB0078INSTRUCCIONES DE INSTALACIÓNEXCLUSIVAMENTE PARA COCINAS DOMÉSTICASINSTALADOR: ENTREGUE ESTE MANUAL AL PROPIETARIO DE LA

Page 28 - 19. ENTRETIEN

34PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIÓN CORPORAL, RESPETE LAS SIGUIENTES INDICACIONES:1. Utilice esta unidad únicamente de

Page 29 - 20. FONCTIONNEMENT

35HL0122- SISTEMAS CON EL GRUPO DE ALIMENTACIÓN -CP34, CP35 Y CP37MODELO 634 O 644(TAPA DE TECHO)MODELO 643(CAPUCHÓN MURAL REDONDO DE 8”)MODELO 418(CO

Page 30 - 21. GARANTIE

361. PREPARACIÓN DE LA INSTALACIÓNPlanifique el lugar y la forma en que instalará los tubos. Para la conexión de los tubos es preferible acceder por

Page 31 - 22. SCHÉMA ÉLECTRIQUE

373. PREPARACIÓN DE LA CAMPANA A MEDIDA (CONTINUACIÓN)Para minimizar el espacio alrededor del grupo de alimentación, tomar las medidas de la anchura

Page 32 - 23. PIÈCES DE REMPLACEMENT

386. DESMONTAJE DEL RIEL DE VERTIDO DE LA GRASAA. Levante el riel para desprenderlo del tablero inferior.B. Deslice el riel completamente a la izquie

Page 33 - SERIES CP34, CP35 Y CP37

3910. INSTALACIÓN DEL ADAPTADOR Y DISPOSITIVO DE CIERRE (MODELO CP37 EXCLUSIVAMENTE)Utilice 2 tornillos n.° 8 x 3/8” de la bolsa de piezas para insta

Page 34 - PRECAUCIÓN

41. PREPARE INSTALLATIONPlan where and how the ductwork will be installed. Access to the top of the hood is preferred for connection of ductwork. Inst

Page 35 - CP34, CP35 Y CP37

4012. DESMONTAJE DE LOS VENTILADORESPara facilitar la alineación del grupo de alimentación con los tubos, desenchufe y desmonte los ventiladores del

Page 36 - ADVERTENCIA

4113. INSTALACIÓN DEL GRUPO DE ALIMENTACIÓNPRECAUCIÓNProcure no doblar los tubos al instalar el grupo de alimentación.Utilice los tornillos cromados

Page 37 - 5. DESMONTAJE DE LOS FILTROS

4214. REINSTALACIÓN DE LOS VENTILADORES (CONTINUACIÓN)Enchufe los ventiladores.HE0085TODOS LOS MODELOS15. REINSTALACIÓN DEL TABLERO INFERIORLevante

Page 38 - VISTA LATERAL

4317. REINSTALACIÓN DE LOS FILTROSPRECAUCIÓNRetire la película protectora de plástico que cubre los filtros antes de instalarlos.NOTA: Instale las m

Page 39 - 11. CONEXIÓN DEL CABLEADO

4419. USO Y CUIDADOPlacas de los filtrosLos filtros deben limpiarse con frecuencia. Utilice una disolución de detergente con agua templada. Lávelos co

Page 40 - MODELO CP37

4520. FUNCIONAMIENTOPonga en marcha siempre la campana antes de empezar a cocinar para generar una corriente de aire en la cocina. Deje en marcha el v

Page 41

4621. GARANTÍAGARANTÍA LIMITADA DE UN AÑOBroan-NuTone LLC (“Broan-NuTone”) garantiza al comprador original de sus productos que éstos carecen de defec

Page 42 - CONTINUACIÓN)

4722. DIAGRAMA ELÉCTRICOLÍNEAHILO NEUTROTIERRA120 V CABMMAZRMMAZRNBCONTROL DEVELOCIDADTERMOSTATOHSAZNNAZNBBBBNNAAL 12AZAZAZAZCÓDIGO DE COL

Page 43 - 18. BOMBILLAS

4823. PIEZASSeries CP34, CP35y CP37 de BestHL011010111215141613123456789SUSTITUCIÓN DE PIEZAS Y REPARACIÓNPara que la unidad se conserve en buen estad

Page 44 - 19. USO Y CUIDADO

53. CUSTOM HOOD PREPARATION (CONT’D)To minimize the gap around the power pack, take actual width and depth measurements of power pack and add 1/16” t

Page 45 - 20. FUNCIONAMIENTO

66. REMOVE GREASE DRIP RAILA. Lift grease drip rail to disengage it from the bottom panel.B. Slide grease rail all the way to the left or right () a

Page 46 - 21. GARANTÍA

710. INSTALL ADAPTER AND DAMPER (CP37 MODEL ONLY)Using 2 no. 8 x 3/8” screws from parts bag, assemble the adapter on the top of the power pack. Seal

Page 47 - 22. DIAGRAMA ELÉCTRICO

812. REMOVE BLOWER(S)In order to ease the power pack alignment with existing ductwork, unplug and disassemble the blower(s) from the power pack before

Page 48 - 23. PIEZAS

913. INSTALL POWER PACKCAUTIONTake care not to kink ducting when installing the power pack.Using provided no. 8 x 1/2” chrome plated screws, install

Comments to this Manuals

No comments