INSTALL FILTERS
(NON-DUCTED HOODS ONLY)
1. Install a charcoal filter on each side of the
blower (included with Nonducted
Recirculation Kit Model ANKU10).
2. To install the charcoal filter, align two keyhole
slots on the filter with locking tabs on the
blower. Rotate to lock filter into place.
3. To remove the charcoal filter, rotate the filter
until it disengages from the blower.
NON-DUCTED
RECIRCULATION FILTERS
INSTALL ELECTRICAL
WARNING: All electrical wiring should
be done by a qualified person (s) in
accordance with all applicable codes and
standards. This range hood must be
properly grounded.
1. Run 120 VAC electrical power cable to the
hood’s wiring box.
2. From inside the hood, remove the wiring box
cover.
3. Secure the conduit to the wiring box through
a conduit connector.
4. Make electrical connections at the hood.
Connect white-to-white, black-to-black and
green to ground.
5. Replace the wiring box cover and screws.
Make sure the wires are not pinched
between the cover and box.
6. Connect power at the service entrance and
check hood for operation.
!