Best WC45E90SB User Manual

Browse online or download User Manual for Cooker hoods Best WC45E90SB. BEST WC45E90SB User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
In USA - BEST Hartford, Wisconsin
In CANADA - BEST Drummondville, QC, Canada
Model WC45
ENGLISH........................................3
FRANÇAIS...................................25
ESPAÑOL.....................................49
REGISTER YOUR PRODUCT ONLINE AT : www.BestRangeHoods.com/register
For additional Information visit www.BestRangeHoods.com
Page view 0
1 2 3 4 5 6 ... 71 72

Summary of Contents

Page 1 - Model WC45

In USA - BEST Hartford, WisconsinIn CANADA - BEST Drummondville, QC, CanadaModel WC45ENGLISH...3FRANÇAIS...

Page 2

- 10 -INSTALL THE DUCTWORKNOTE: To reduce the risk of fire, use onlymetal ductwork.1. Decide where the ductwork will runbetween the hood and the outsi

Page 3 - WARNING

- 11 -EXTERNAL BLOWER ELECTRICAL CONNECTIONSBlower connection at hood:1. Run 2-wire plus ground power cable fromthe Exterior or In-Line Blower to the

Page 4 - CAUTION

- 12 -INSTALL MOUNTINGBRACKETSRemove the plastic protective film from allexterior surfaces, decorative flues and filters,prior to final installationDU

Page 5 - CLEANING AND MAINTENANCE

- 13 -MOUNTING SCREWS(4.8 x 38mm)MOUNTING SCREWS(3.9 x 6 mm Flat Head)INSTALL FLUE MOUNTINGBRACKETDUCTED AND NON-DUCTED1.Assemble the flue mounting br

Page 6 - OPERATION

- 14 -DUCTED INSTALLATION ONLYNote: Rooms with 10 or 11 foot ceilingrequire flue extension modelAEWC345IQSB, available from yourlocal dealer. Discard

Page 7 - PREPARE THE HOOD

- 15 -NON-DUCTED INSTALLATION ONLYNote:a. Purchase Model ANKWC345 Non-ductedRecirculation Kit from your local dealer.b. Rooms with 10 or 11 foot ceili

Page 8 - EXTERIOR BLOWER

- 16 -7. Temporarily secure the upper and lowerflue together with duct tape as shown(Fig.21).8. Lift the flue into position above the hood.Secure uppe

Page 9 - IN-LINE BLOWER

- 17 -FIG. 25FIG. 26INSTALL FILTERSDUCTED AND NON-DUCTED HOODSNOTE: prior to use, remove protective filmfrom the filter frame.1. To remove the GREASE

Page 10 - INSTALL ELECTRICAL

- 18 -CALIBRATE IQ BLOWER SYSTEMTMINTERNAL BLOWER DUCTED UNITS ONLYAfter the hood is installed and wired, engage the calibration process (our Guarante

Page 11 - BLOWER CONNECTION AT HOOD

- 19 -WARRANTYONE YEAR LIMITED WARRANTY FOR BEST PRODUCTSBroan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Best products

Page 13 - INSTALL THE HOOD

- 20 -KEY NO. PART NO. DESCRIPTION9 B08087806 Grease Filters37 B02300804 Heat Sentry60 B02300249 Feeder Cable67 B06102615 Wires Assembly73 B002090377

Page 14

- 21 -

Page 15 - MOUNTING SCREWS

- 22 -KEY NO. PART NO. DESCRIPTION9 B08087806 Grease Filters37 B02300804 Heat Sentry60 B02300249 Feeder Cable67 B06102616 Wires Assembly73 B002090377

Page 18 - CALIBRATE IQ BLOWER SYSTEM

- 25 -Aux États-Unis - BEST Hartford, WisconsinAu CANADA - BEST Drummondville, QC, CanadaModèle WC45ENGLISH...3FR

Page 20 - SERVICE PARTS

- 27 -LIRE CES DIRECTIVES ET LES CONSERVERCONÇUE POUR LES CUISINES PRIVÉES UNIQUEMENT!! AVERTISSEMENTSPOUR RÉDUIRE LES RISQUES D’INCENDIE, D

Page 21

- 28 - AVERTISSEMENTSPOUR RÉDUIRE LE RISQUE DE BLESSURES PHYSIQUES EN CAS DE FEU DE FRITURESUR LA TABLE DE CUISSON, VEUILLEZ PROCÉDER COMME

Page 22

- 29 -AMPOULES DELCette hotte comprend des ampoules LED qui n’exigent aucun entretien.NETTOYAGE ET ENTRETIENPour assurer les performances de l'ap

Page 23

- 3 -READ AND SAVE THESE INSTRUCTIONS WARNINGTO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVETHE FOLLOWING:1. Use this unit

Page 24

- 30 -Bouton TC1 (Lumières)Commutateurs de lumière principale ON / OFFBouton TC2 (moteur -V1)Moteur ON / OFF - Active le moteur à vitesse 1.Bouton TC3

Page 25 - Modèle WC45

- 31 -SUPPORT DEMONTAGE DUCARNEAU8 VIS DE MONTAGE (àtête cylindrique de 4,8 x38 mm)CARNEAUDÉCORATIFCOLLIERD’EVACUATION4 VIS DE MONTAGE(à tête plate de

Page 26

- 32 -CHOIX DE VENTILATEUR EXTERNE OU “IN-LINE” WC45E SeriesATTENTION: Pour réduire les risques d’incendie et électrique, installer cette hotteseuleme

Page 27 - AVERTISSEMENTS

- 33 -VENTILATEUR IN-LINEFIG. 5

Page 28 - ATTENTION

- 34 -INSTALLER LES CONDUITSREMARQUE: pour réduire les risquesd’incendie, utilisez uniquement desconduits métalliques.1. Décidez de l’emplacement des

Page 29 - NETTOYAGE ET ENTRETIEN

- 35 -CONNEXIONS ÉLECTRIQUES DU VENTILATEUR EXTÉRIEURRaccordement du ventilateur à la hotte :1. Acheminez un câble électrique à deux fils plus un fil

Page 30 - FONCTIONNEMENT

- 36 -INSTALLATION DES BRIDESDE MONTAGERemarque : avant l'installation finale,retirez la pellicule en plastique de toutesles surfaces extérieures

Page 31 - PRÉPARATION DE LA HOTTE

- 37 -VIS DE MONTAGE(4.8 x 38mm)VIS DU SUPPORT(À TÊTE PLATE DE 3,9x9,5mm)INSTALLATION DU SUPPORT DEMONTAGE DU CARNEAUHOTTES CANALISÉES ET NON CANALISÉ

Page 32 - VENTILATEUR EXTERNE

- 38 -INSTALLATION D’UNE HOTTE CANALISÉERemarque: Les chambres avec plafondde10 ou 11 pieds, exigent le carneaud’extension, modèle AEWC345IQSB,dispon

Page 33 - VENTILATEUR IN-LINE

- 39 -VIS DE MONTAGE(À TÊTE PLATE DE3.9 x 6 mm)FIG. 20CONDUITRACCORDFIG. 19FIG. 17FIG. 18INSTALLATION HOTTE NON CANALISÉEUNIQUEMENTRemarque:a. Veuille

Page 34 - INSTALLER LES CONDUITS

- 4 - WARNINGTO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASEFIRE, OBSERVE THE FOLLOWING:*1. SMOTHER FLAMES with a close-f

Page 35

- 40 -FIG. 21FIG. 22FIG. 23FIG. 247. Fixez temporairement les conduitssupérieur et inférieur ensemble avec duruban à conduit, tel qu’illustré (Fig. 21

Page 36 - DE MONTAGE

- 41 -FIG. 25FIG. 26INSTALLATION DES FILTRESHOTTES CANALISÉE ET NON CANALISÉEREMARQUE : Avant l’utilisation, enlevez lapellicule protectrice sur le c

Page 37 - INSTALLATION DE LA HOTTE

- 42 -CALIBRAGE DU VENTILATEUR IQMCVENTILATEUR INTERNE AVEC CONDUITS SEULEMENTUne fois la hotte installée et connectée, enclenchez le processus de cal

Page 38

- 43 -SETUP 1SETUP 1SETUP 2SETUP 2SETUP 3SETUP 3EB6ILB3ILB6EB12EB15ILB9EB9ILB11GARANTIE LIMITéE DE UN AN DE BESTBroan-NuTone LLC (Broan-NuTone) garant

Page 39

- 44 -N. PART NO. DESCRIPTION9 B08087806 Filtres à graisse37 B02300804 Capteur de température60 B02300249 Cordon d’alimentation67 B06102615 Ensemble d

Page 40

- 45 -

Page 41 - INSTALLATION DES FILTRES

- 46 -N. PART NO. DESCRIPTION9 B08087806 Filtres à graisse37 B02300804 Capteur de température60 B02300249 Cordon d’alimentation67 B06102616 Ensemble d

Page 44 - PIÈCES DE RECHANGE

- 49 -En EE.UU.: BEST Hartford, WisconsinEn CANADÁ - BEST Drummondville, QC, CanadaModelo WC45ENGLISH...3FRANÇAIS

Page 45

- 5 -LED LAMPSThe hood is provided with LED lamps wich require no maintenance.CLEANING AND MAINTENANCEProper maintenance of the Range Hood will assure

Page 46

- 50 -

Page 47

- 51 -LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIAPARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONESPERSONALES, RESPET

Page 48

- 52 - ADVERTENCIAPARA REDUCIR EL RIESGO DE LESIONES PERSONALES EN CASO DE UN INCENDIO PORGRASA EN LA COCINA, RESPETE LO SIGUIENTE: *1. SO

Page 49 - Modelo WC45

- 53 -LAMPARAS LEDLa campana cuenta con lámparas LED que no requiren mantenimiento.LIMPIEZA Y MANTENIMIENTOEl mantenimiento adecuado de la campana pa

Page 50

- 54 -Botón TC1 (Luces)Interruptores principal luz de encendido / apagadoBotón TC2 (Motor -V1)Motor ON / OFF - Activa el motor en primera velocidad.Bo

Page 51 - ADVERTENCIA

- 55 -PREPARACIÓN DE LA CAMPANADesensamble la campana y revise el contenido.Debe recibir:1 - Campana1 - Conjunto de conducto de chimenea decorativa1 -

Page 52 - PRECAUCIÓN

- 56 -CAMPANACHIMINEADECORATIVAOKOKSUGERENCIAS DE COLOCACION YINSTALACIONVENTILADOR EXTERIORPRECAUCION: PUEDE NOENTRAR DEBAJO DE TEJAS OCASAS DE UN SO

Page 53 - LIMPIEZA Y MANTENIMIENTO

- 57 -VENTILADOR “IN-LINE”FIG. 5

Page 54 - FUNCIONAMIENTO

- 58 -INSTALACION DEL CONDUCTODE EXTRACCIÓNNOTE: To reduce the risk of fire, use onlymetal ductwork.1. Decida dónde instalará el conducto entrela camp

Page 55 - PREPARACIÓN DE LA CAMPANA

- 59 -CONEXIONES ELÉCTRICAS DEL VENTILADOR EXTERNOConexión del ventilador en la campana:1. Tienda un cable eléctrico de dos hilos y conexión a tierra

Page 56 - VENTILADOR EXTERIOR

- 6 -Button TC1 (Lights)Switches main light ON/OFFButton TC2 (Motor-V1)Motor ON/OFF - Activates the motor at 1st speed.Button TC3 (Motor-V2)Activates

Page 57 - VENTILADOR “IN-LINE”

- 60 -INSTALACIÓN DE LOSSOPORTES DE MONTAJERemueva la película plástica protectora detodas las superficies exteriores,chimeneas decorativas y filtros,

Page 58 - INSTALACIÓN ELECTRICA

- 61 -TORNILLOS DEMONTAJE (4,8x38mm)TORNILLOS DE MONTAJE(3.9 x 6mm Cabeza troncoconica)RETIRE (2)TORNILLOS DEMONTAJE 3.9 x 9.5 mmCAJA DELSISTEMAELÉCTR

Page 59 - EL VERDE A LA TOMA DE TIERRA

- 62 -INSTALACION CON DUCTO SOLAMENTENota: Habitaciones con techos de 10 o11 pies de altura requieren tubería deescape modelo AEWC345IQSB,disponible c

Page 60 - SOPORTES DE MONTAJE

- 63 -FIG. 20FIG. 19FIG. 17FIG. 18CONECTOR DECONDUCTOTORNILLOS DEMONTAJE(3,9 x 6 mm Cabeza plana)INSTALACIONES SIN DUCTO SOLAMENTENota:a. Compre un ju

Page 61 - INSTALACIÓN DE LA CAMPANA

- 64 -FIG. 21FIG. 22FIG. 23FIG. 247. Asegure juntos temporalmente el tubo dehumos superior e inferior con cinta paraconductos, como se muestra (Fig. 2

Page 62 - FIG. 16FIG. 15

- 65 -FIG. 25FIG. 26INSTALACION DE FILTROSCAMPANAS CON O SIN DUCTOSNOTA: Antes de utilizar este producto,despegue la película protectora del bastidord

Page 63 - FIG. 20FIG. 19

- 66 -LUZ DECALIBRACIONBOTON DECALIBRACIONCALIBRACIÓN DEL VENTILADOR IQTMSOLO UNIDADES CON CONDUCTOS DE VENTILADOR INTERNODespués de instalar y cablea

Page 64

- 67 -PROCEDIMIENTO DE MODO DE PROGRAMACIÓN WC45EProcedimiento de modo de programación WC45ELa campana de cocina está diseñada para trabajar con difer

Page 65 - INSTALACION DE FILTROS

- 68 -N° PIEZA N° DESCRIPCIÓN9 B08087806 Filtros de grasa37 B02300804 Sensor de temperatura60 B02300249 Cable de alimentación67 B06102615 Ensamble de

Page 67 - GARANTIA

- 7 -PREPARE THE HOODUnpack hood and check contents.You should receive:1 - Hood1 - Decorative Flues1 - Parts Bag (B080810993) containing:2 - Mounting

Page 68 - PIEZAS DE REPUESTO

- 70 -N° PIEZA N° DESCRIPCIÓN9 B08087806 Filtros de grasa37 B02300804 Sensor de temperatura60 B02300249 Cable de alimentación67 B06102616 Ensamble de

Page 69

- 71 -

Page 70

04308407/399045175C

Page 71

- 8 -EXTERIOR AND IN-LINE BLOWER SELECTION WC45E SeriesCAUTION: To reduce risk of fire and electric shock, install this range hood only with BestExte

Page 72 - 99045175C

- 9 -IN-LINE BLOWERFIG. 5