10. INSTALL THE ADAPTER (P5 AND P8 BLOWERS ONLY)
Using provided screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood using metal foil duct tape.
NOTE: For vertical exhaust, ensure that the damper pivot is located towards the front of the hood.
HD0005 HD0006
YOU MUST install the deviator if you choose to vent the hood vertically. Install the deviator as
shown.
NOTE: If installed correctly, the deviator will protrude about 1/8” above the rough-in plate.
8. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS)
INTERIOR BLOWER: Secure the rough-in plate (provided with the
blower) inside the hood with four lock nuts. See
picture at right.
EXTERIOR OR IN-LINE BLOWER: Refer to instructions included with
exterior or in-line blower rough-in kit.
Secure the rough-in plate inside the
hood with four lock nuts.
9. INSTALL THE DEVIATOR (P5 AND P8 BLOWERS, VERTICAL INSTALLATION ONLY)
HD0003
Inserting deviator into hood vertical opening.
HD0048
BLOWER PLATE
LOCK NUTS
Attach 8” round adapter/damper to blower rough-in plate.
Use metal duct tape to make all joints secure and air-tight.
7. INSTALL THE ADAPTER/DAMPER (P3, P6 AND IQ6 BLOWERS ONLY)
HO0196